Kilowatt-hour meter    
HOME / Kilowatt-hour meter / Three phase (multi-function with data log)
♦Three phase
(multi-function with data log)♦

# 1_17




Details description

1. Function

1.1 Measure function:

Can measure following data

Active Currently Positive total, sharp, peak, shoulder, off-peak active energy
Currently Reverse total, sharp, peak, shoulder, off-peak active energy
This month, last month, last 2 month … last 12 month, Positive total, sharp, peak, shoulder, off-peak active energy
This month, last month, last 2 month … last 12 month, Reverse total, sharp, peak, shoulder, off-peak active energy
Reactive Currently Positive total, sharp, peak, shoulder, off-peak reactive energy
Currently Reverse total, sharp, peak, shoulder, off-peak reactive energy
This month, last month, last 2 month … last 12 month, Positive total, sharp, peak, shoulder, off-peak reactive energy
This month, last month, last 2 month … last 12 month, Reverse total, sharp, peak, shoulder, off-peak reactive energy
I, II, III, IV Quadrant reactive energy
Demand Currently Positive total, sharp, peak, shoulder, off-peak active Max. demand and happen time
Currently Reverse total, sharp, peak, shoulder, off-peak active Max. demand and happen time
This month, last month, last 2 month … last 12 month, Positive total, sharp, peak, shoulder, off-peak active Max. demand and happen time
This month, last month, last 2 month … last 12 month, Reverse total, sharp, peak, shoulder, off-peak active Max. demand and happen time
Currently Positive total, sharp, peak, shoulder, off-peak reactive Max. demand and happen time
Currently Reverse total, sharp, peak, shoulder, off-peak reactive Max. demand and happen time
This month, last month, last 2 month … last 12 month, Positive total, sharp, peak, shoulder, off-peak reactive Max. demand and happen time
This month, last month, last 2 month … last 12 month, Reverse total, sharp, peak, shoulder, off-peak reactive Max. demand and happen time
I, II, III, IV Quadrant Max. demand
Instant A, B, C Phase voltage
A, B, C Phase current
Frequency
Temperature
Constant
Baud rate
Power
Date, time, Week
Phase

1.2 Multi-tariff function

Have 4 kinds of tariff (sharp, peak, shoulder, off-peak)

12 pieces of time of period (one day can divide to 12 period)

12 pieces of daily time of period table (time period table)

12 pieces of time zone (one year can divide to 12 parts)

7 pieces of weekend day

12 pieces of public holiday

3 days of spring festival

1.3 Data Log function

Have six kinds of load curve data log

Interval time can be set in 1~99 minute.

The six kinds of data log is:

1 kind: active total energy, positive active total energy, reverse active total energy;

2 kind: reactive total energy, I quadrant reactive energy, IV quadrant reactive energy, II quadrant reactive energy, III quadrant reactive energy;

3 kind:A phase voltage, B phase voltage, C phase voltage

4 kind: A phase current, B phase current, C phase current

5 kind: total power factor, A phase power factor, B phase power factor, C phase power factor

6 kind: instant reactive power, A phase reactive power, B phase reactive power, C phase reactive power

other data log

phase cut record

over voltage

over current

lose voltage

lose current

open cover

current imbalance

over power

over demand

voltage reverse phase sequence

current reverse phase sequence

set clock

energy reset

demand reset

meter programme

power cut / on

voltage qualified rate

meter total reset

1.4 Communication function

RS485 port

Infrared

1.5 Outputfunction

Active and reactive pulse output

Clock signal output

1.6 Display function

LCD display

Auto circle , the display content and interval time can be set

With double display keyboard

LCD with backlight

1.7 Warning function

Lose voltage light and sound warning

Lose current light and sound warning

Reverse phase sequence light and sound warning

Open cover LCD display warning

Power cut LCD display warning

2 Feature

Daily clock error not more than 0.5s/day, power cut is 1.0s/day

Max. demand distinguish: active 0.0001kW; reactive 0.0001kvar

Total pulse output width: 80ms 20ms

Power cut power loss: maintain current ≤30μA (battery voltage 3.6V)

Power cut the data can keep more than 10 years.

Rated voltage: 3X230/400V (3P 4W), 3X100V (3P 3W)

Rated frequency: 50Hz

Class : active 0.5S or 0.5 or 1 ; reactive 2

Basic current: 3X1.5(6)A, 3X5(20)A, 3X10(40)A

Power loss: voltage circuit not more than 1.5W/5VA, current circuit not more than 1VA

Temperature:

Standard work temperature: -30℃~55℃

Limited work temperature: -40℃~65℃

Relative humidity: ≤85%

3. Drawing

 