Kilowatt-hour meter    
HOME / Kilowatt-hour meter / Three-phase (Multi-function with data log and buit-in GPRS)
♦Three-phase
(Multi-function with data log and buit-in GPRS)♦

# 1_18



Details description

1. Summarize

Adopt three-phase doulbe-way power/energy measure chip and SMT manufacture workmanship, with high measure accuracy and stability

The main circuit is new type EMI (Electro Magnetic Interference) Resistance SCM Mico-computer, digital AD sampling Chip is measure unit, with advance technical, reasonable design, high measure and control accuracy, running reliable, and with stronger disturb self-recover ability. With harmonic energy measure function, and six kinds of load curve record function.

The meter accord with national and electric power industry standard: GB/T17215-200, GB/T15284-2002, DL/T614, and DL/T645.

2. Working principle

See following drawing, the tested three-phase voltage and current pass to separated sampling circuit, transform to relevant signal input to three-phase double-way power/energy measure integrate circuit, the output is frequency pulse signal direct ratio to tested three-phase power, after frequency calculate realize three-phase energy measure by CPU.

3. Specification and main technical data

3.1 Three-phase four-wirethree-phase three-wire

3.2 Specification and energy testing pulse constant

Type Specification Testing pulse constant (imp/kWh)
3-phase 4-wire 3×220/380V 3×1.5(6) A 6400
3×5(20) A 1600
3×10(40)A 800
3×15(60) A 800
3×20(80) A 400
3×30(100)A 200
3-Phase 3-wire 3×100V 3×1.5(6) A 6400

3.3 Class: 0.5, 1 or 2

3.4 Rated Frequency:50Hz

3.5 Power Loss: voltage circuit:≤ 2W and 10VAcurrent circuit:≤ 0.6VA

3.6 Tariff rate work parameter

Daily time accuracy:≤±0.5s/d(23±3℃), Power cut daily time accuracy:≤±1.0s/d

Max. Demand distinguish rate is 00.0001kW

Power cut power loss: maintain current≤70uA (battery voltage 3.6V, 32768Hz crystal shake work)

3.7 voltage infection: the voltage changed in ±20% with good stability

3.8 Entironment condition:

3.8.1 work temperature: -20℃~+45℃

3.8.2 limited work temperature:-40℃~+60℃

3.8.3 relative humidity:

annual average:≤75%

30days, nature distributing in a year:≤95%

in other date:≤85%

3.9 Weight: about 2Kg

3.10 Appearance size: 278mm × 175mm × 80mm

3.11 Surface install technology: SMT

4. Main function

4.1 time switch

4.1.1 Permit setting 12 sets daily time of period,can divide 12 time zone in one year.

4.1.2 Each set time of period can has Sharp, Peak, Shoulder, Off-peak four kinds of tariff rate, time interval in minimum can be 1 minute.

4.1.3 with weekend day set function

4.1.4 Balance date every month can be programmed, data is saved automatically

4.1.5 Power cut in month end still the data can be calculated and save

4.2 Multi-tariff (time-sharing) energy measure

4.2.1 Measure positive Total, Sharp, Peak, Shoulder, Off-peak and reverse accumulative total energy and whole hour energy accumulative value in last month.

4.2.2 The energy display decimal digits can be set

4.3 Max demand measure

4.3.1 Max demand period can be selected in sliding windows time or fixup time

4.3.2 Measure nonce month and save max demand value and happen time of last month total, sharp, peak, shoulder, off-peak

4.4 Display

4.4.1 Special wide temperature LCD display

4.4.2 Power cut LCD auto display data

4.4.3 The display content and period can be set

4.5 Program and data communication

4.5.1 With the function of infrared remote control program, hand computer program, RS485 long distance communication program

4.5.2 Last program date and times auto saved, the data communication with many verify, assure the correct and credibility

4.5.3 Program operate with switch (hardware) and password (software) double protection

4.5.4 Opening data communication, easy for the conversion of different communication protocol

4.6 With self check function in display circuit, RAM, EEPROM and WDT

4.7 Good electromagnetism compatibility, the design have inner,outer double WDT circuit, machine die auto recover. Power cut with supper lower power loss. Data is saved forever in power cut

4.8 Battery voltage lack-voltage or lose voltage warning automaticly

4.9 Phase cut data record

4.9.1 Record A, B, C phase cut time and times

4.9.2 Record the energy used when one phase cut, two phase cut

5. Daily time accuracy’s adjusting and testing of time switch

The time switch use high accuracy time chip, has crystal-shake frequency testing point, the testing port output 1Hz signal to test crystal-shake frequency.

The frequency and daily time accuracy as following:

Daily time accuracy ±0.5s
1Hz frequency accuracy 1±5×10-6Hz

6. Program switch setting

The inner built-in program lock switch, when press down the switch, will permit program of hand-computer or communication port, i.e. set running parameter. 5 minute later cancel program function automatic, forbidden hand-computer or communication port program.

7. Communication circuit and interface

7.1 with RS485 and infrared communication port

7.2 infrared carry wave frequency is 38KHz, COM communication baud rate is 1200bps

7. 3 the communication protocol confirm to the standard of electric power department DL / T645<>

8. Six kinds of load curve record function

As per the time alternation Set by user,can Log six kinds of data in roll

Alternation time is 1~99 minute, can be set by user, the six kinds sampling data is:

First kind: Active total energy consume, positive active total energy consume, reverse active total energy consume

Second kind: Reactive total energy consume, I quadrant Reactive energy consume, IV quadrant reactive energy consume, II quadrant reactive energy consume, III quadrant reactive energy consume.

Third kind: A phase voltage, B phase voltage, C phase voltage

Fourth kind: A phase current, B phase current, C phase current;

Fifth kind: Total power factor, A phase power factor, B phase power factor, C phase power factor

Sixth kind: instant Reactive power, A phase reactive power, B phase reactive power, C phase reactive power

The details data can be see by PC software.

The six kinds of data with Min.64K memory capability, Max.is 64KX4, it can be selected by user in 64K, 64K×2,64K×3,64K×4

9. Harmonic wave energy measure function

9.1 Distinguish from electricity user, find who is bring humorous wave, and who is suffer injury by humorous wave.

9.2 Measure harmony wave, indication humorous wave tideway direction

10. GPRS copy meter terminal

Realize long distance automatic copy meter, can reduce the number of person and fee for copy metr, avoid manual work’s fault (miss copy, mistake copy, estimate copy)

11. LCD display

11.1 LCD display structure

Explain:

Left 4 small figure is code; the other 8 figures is number area

The above of left 4 figures is currently tariff rate indication

11.2 Display explain

Symbol Explain
Unit: kWh—Active EnergykW—Max DemandAh—Amp. Hour kvarh—Reactive Energykvar—Reactive DemandV-Voltage A-Current
Program When press down program keyboard it will display, means now permit program
Battery state: when voltage lower than 3V, it is display, means need replacing battery.
Warning indication(if has fault it will display, not be controlled by control bytes)*Note: the fault main include: lose-voltage, lose-current, reverse phase sequence, over load, battery lack of voltage, over voltage, Memorizer bad, power cut etc.
Comm. Lighting when 485 or infrared communication
Ia Ib Ic Separate means A-Phase B-Phase C-Phase lose current, when losing, it is twinkle, if current is normally not lighting. *Note: in 3phase 3wire meter, without B phase current, not display B phase lose current
Ua Ub Uc Separate means Ua, Ub, Uc lose voltage, lose voltage, power cut in twinkle display*Note: in 3phase 3phase meter, B phase voltage is Uac voltage
Separate means currently working quadrant
Positive The reading data is positve energy, demand and demand happen time
Negative The reading data is reverse energy, demand and demand happen time
Active The reading data is active energy, demand and demand happen time
Reactive The reading data is reactive energy, demand and demand happen time
Date Currently meter running date
Time Currently meter running time
Week Currently meter running week. On Sunday, Lcd display is “7”
Period of time Display when reading period of time, means period of time data
Time zone Display when reading time zone, means time zone data
Energy Display when reading energy, means accumulative energy
Demand Display when reading demand, means accumulative demand
Meter No. Meter number(12digits), the high 6 digits is “H-XXXXXX”, lower 6 digits is “L-XXXXXX”
User No. Meter User No.(12digits), the high 6 digits is “H-XXXXXX”, lower 6 digits is “L-XXXXXX”
Phase cut Display when reading phase cut , means phase cut time and times
winter Display when meter running in winter, means the currently period of time is winter period
times Means meter cover open times, phase cut times
Open up cover is lighting
Open lower cover is lighting
Power cut When power cut is lighting, means now without electricity
Constant Active, reactive constant
Bps Communication speed
Currently meter inner temperature

11.3 Display mode

There’s two kinds of ways display data

11.3.1 Auto display in roll:

Roll display time: the display time for each data, the time alternation can be set in 1~99s

Display content: the display content can be set as per requirement

11.3.2 Reading data by hand:

Press the keyboard on the meter, can read meter data and set parameter. It doesn’t relate with setting display content. (Whatever the item is in the roll display range, all item can be read by reading keyboard. When meter is in the roll display state, after reading data by keyboard, 15s later come into roll display automaticly, and start from first item)

In meter has two keyboard for reading data, the left is for pages change, this keyboard can read details data; the right is for items change, press this keyboard can see next item data.

12. Structure description

12.1 Install and connections

12.1.1 Indoor Install, in airiness and air-dry place, insure the safety and credibility; if in dirtiness or maybe damage meter place, the protect cabinet is needed for the meter

12.1.2 in the top of the meter has pothook bolt hole, fixed by M4X10 bolt, in the bottom of meter has 2 install hole, fixed by PA4X10 or PA4X12 self-attack bolt. As per the size in above drawing, drill hole first, the base fixed in the object of firmly, fireproof and shakeproof

12.1.3 the meter should correct connecting as per connect drawing. The leadin suggest use copper wire or copper tie-in, the bolt in terminal should screw down, avoid heat and burn for badness contact or thin leadin

12.2 Function terminals

12.3 Power supply terminals

CT (current transformer) type: 3X230/400V 3X1.5(6) A

Direct connect type: 3X230/400V ≥3X5 (20) A

CT (current transformer), PT (Potential transformer) type: 3X57.7/100V 3X1.5(6)A

CT (current transformer), PT (Potential transformer) type: 3X100V 3X1.5(6) A

Testing pulse interface

Clock interface

13. Function and features

13.1 three-phase energy measure, long time working no need adjustment

13.2 three-phase power supply, one or two phase cut, the measure accuracy not be infected

13.3 widely working temperature range

13.4 with energy testing signal output


GPRS Copy Meter explain

1. Summarize

GSM/GPRS auto copy meter groupware is adopt GPRS module opened wireless transparency data transfer product. The product is based on mobile GPRS net, with high capability, high credibility and anti-jamming features. Transfer speed is high, has long distance testing and supervise function.

2.structure composing

GSM/GPRS is composed by GPRS service and GPRS terminal. GPRS service has standard RS232 port,can be connected with computer directly; GPRS terminal has standard RS485 port, can be connected with meter.

3. Main technical parameter

3.1 support 900/1800/1900MHz three frequency GPRS

3.2 interface: RS232 and RS485 (with over voltage ,over current protect).

3.3 Support WindowsXP/2000 system

3.4 Transfer speed: 9600bps

3.5 protocol: DL645 communication protocol and collector inner communication protocol

3.6 power supply :Rated voltage: AC220V±10%

3.7 working temperature:-25℃~+85℃

4.function and features

4.1 real time capability is better:

As GPRS can be real-time online, so the device without time delay

4.2 Can long distance control meter.

Through GPRS can realize the long distance control, adjust meter parameter, control meter rely switch etc.

4.3 Low cost

As using GPRS wireless public net, so long as install the device it can be worked, no need special lines, prophase low invest, take effect faster, anaphase upgrade, maintain cost is low

4.4 Copy meter range is wide:

GPRS cover range is wide, in the range of GSM/GPRS net, all can be finished the control and manage for copy meter.

4.5 The Groupware with big transfer capability:

the data collect center will keep real time connect with every collect point.GPRS technology can satisfied with the requirement

4.6 data transfer speed is faster:

each user data collect point has 10Kbps data transfer in everytime. GPRS transfer speed can be reach to 171.2kbit/s in theory, at present the real transfer speed is about 40kbit/s, can be satisfied with the spreed requirement(≧10kbit/s)

4.7 Communication fee is low: the GPRS data communication cost is low

4.8 Easy operation: with software support, easy for operation.

 